Micro-modular PLC Splitter is desinged for installing in fiber optic cable connector box. The materials of outside is stainless steel.
Feartures: Small size and Achieve 0.9mm loose tube fiber optic multi-channel direct output without splitter; SC adapterinterface default,can change interface type by the demand of customer; Satisfy with industry standards YD/T893 and YD/T1117.
Applications: Installed in the cable connector box; Installed in the module box; Installed in the distribution box.
Advantages: Not sensitive to wavelength, high uniformity; Resistance to high and low temperature; In line with the Telcordia GR-1209 and GR-1221 reliability requirements; ISO9001 quality system certification.
Performance Specifications:
|
Parameter |
Specification (Not include the loss of connector) |
|
Channel Wavelength (nm) |
1260-1650 |
|
TYPE |
1*4 |
1*8 |
1*16 |
1*32 |
1*64 |
2*4 |
2*8 |
2*16 |
2*32 |
|
Insertion Loss(dB)
|
Typical value |
6.8 |
10.0 |
13.0 |
16.0 |
19.5 |
|
|
|
|
|
Maximum value(P/S) |
7.1/ 7.3
|
10.2/ 10.5
|
13.5/ 13.7
|
16.5/ 16.9
|
20.5/ 21.0
|
7.6 |
11.0 |
14.5 |
17.5 |
|
Uniformity (dB) |
≤0.6 |
≤0.8 |
≤1.2 |
≤1.5 |
≤2.5 |
≤1.5 |
≤1.5 |
≤2.0 |
≤2.5 |
|
PDL (dB) |
≤0.2 |
≤0.3 |
≤0.3 |
≤0.3 |
≤0.4 |
≤0.2 |
≤0.4 |
≤0.4 |
≤0.4 |
|
Return Loss (dB) |
≥50 |
Directivity (dB) |
≥55 |
|
Operating Temperature (°C) |
-40~+85
|
Storage Temperature (°C) |
-40~+85
| * Specifications may change without notice
Ordering Information
|
PPLC |
|
|
|
|
|
|
|
|
|
|
|
Wavelength (nm) |
Grade |
Port |
Package |
Output
Fiber Type |
Cable Diameter |
Fiber Standard |
Input Connector |
Output Connector |
|
|
13=1310 15=1550 16=1260- 1650 |
P=P GRADE S=S GRADE |
102=1*2
104=1*4
108=1*8
116=1*16
132=1*32
164=1*64
202=2*2
204=2*4
208=2*8
216=2*16
232=2*32 |
1=Bare Fiber
2=Pigtail Cassette
3=Rack-mounted
4=Micro-modular
5=Stent Type |
1=1M 2=2M 3=Customized |
1= Φ0.9mm 2= Φ2 mm 3= Φ3 mm |
1=G652
2=G657A
3=G657B |
0=None 1=FC/APC
2=FC/PC
3=SC/APC
4=SC/PC
5=LC/PC
6=ST |
0=None 1=FC/APC 2=FC/PC 3=SC/APC 4=SC/PC 5=LC/PC 6=ST | |